Allied & ICAR Exam Bank • ALLIED_0476 MCQ • 1 Mark

Section 4: Soil and Water Conservation Engineering

Gully Control and Drop Spillways

Subtopic: Gully Control and Drop Spillways

Question Statement:

Anti-seep collars installed around the conduit barrel of a drop inlet pipe spillway serve to:

Options:

  • (A) Increase the seepage flow path along the outside of the pipe barrel by at least $15\%$ to prevent piping and washouts
  • (B) Prevent pipe thermal contraction
  • (C) Increase water velocity inside the barrel
  • (D) Filter sediment from entering the barrel

Answer Key:

A

Step-by-Step Solution & Explanation

Anti-seep collars project into the compacted embankment to interrupt preferential seepage lines and prevent failure by piping along the smooth barrel exterior.