Allied & ICAR Exam Bank • ALLIED_0968 MCQ • 1 Mark

Section 6: Agricultural Process Engineering

Material Handling and Storage

Subtopic: Grain Storage Structures and Design

Question Statement:

During forced aeration of deep grain bulks with ambient night air, the cooling front velocity through the bed is roughly:

Options:

  • (A) $500$ to $1000$ times slower than the interstitial air velocity because of the high heat capacity of grain relative to air
  • (B) Equal to the speed of air
  • (C) Twice the speed of air
  • (D) Zero

Answer Key:

A

Step-by-Step Solution & Explanation

Because the volumetric heat capacity of packed grain ($\rho_g c_g \approx 1200\text{ kJ/(m}^3\cdot\text{K)}$) is nearly 1000 times greater than that of air ($\rho_a c_a \approx 1.2\text{ kJ/(m}^3\cdot\text{K)}$), the thermal front lags vastly behind the airflow.
← Previous (ALLIED_0967) Next (ALLIED_0969) →

Practice In Authentic CBT Exam Interface

Test your skills under authentic timed conditions with live scoring and AIR percentile ranking.

Launch CBT Mock Test