An agricultural watershed of area 200 hectares has a design drainage coefficient of $12\text{ mm/day}$ ($0.012\text{ m/day}$). The required capacity of the main drainage ditch outlet in m$^3$/s is:

Answer Key:

0.278

Step-by-Step Solution & Explanation

Daily volume to be removed $= 200 \times 10,000\text{ m}^2 \times 0.012\text{ m} = 24,000\text{ m}^3/\text{day}$. Discharge $Q = \frac{24,000}{86,400\text{ s}} \approx 0.2778\text{ m}^3/\text{s}$.