Allied & ICAR Exam Bank • ALLIED_3451 NAT • 2 Marks

Section 5: Irrigation and Drainage Engineering

Agricultural Drainage

Subtopic: Non-conventional drainage system

Question Statement:

A subsurface drainage catchment #10 of area A = 29 ha has design drainage coefficient DC = 10 mm/day (0.01 m/day). The design discharge Q = A * DC / 86400 in m^3/s is approx:

Answer Key:

0.0336

Step-by-Step Solution & Explanation

Q = 2900 / 86400 = 0.0336 m^3/s.
← Previous (ALLIED_3450) Next (ALLIED_3452) →

Practice In Authentic CBT Exam Interface

Test your skills under authentic timed conditions with live scoring and AIR percentile ranking.

Launch CBT Mock Test