Allied & ICAR Exam Bank • ALLIED_3590 NAT • 2 Marks

Section 6: Agricultural Process Engineering

Engineering Properties of Agriculture Produce

Subtopic: Electrical properties

Question Statement:

A grain lot #40 has measured bulk density rho_b = 795 kg/m^3 and true density rho_t = 1250 kg/m^3. The porosity epsilon = (1 - rho_b/rho_t) in percent is approx:

Answer Key:

36.40

Step-by-Step Solution & Explanation

Porosity epsilon = (1 - 795/1250) * 100 = 36.40%.