Question Statement:

A tubular pasteurizer operating under the counterflow profile shown has heat capacity rates $C_h = C_c = 4.0\text{ kW/K}$. The overall conductance $U A = 8.0\text{ kW/K}$. Compute the Number of Transfer Units ($NTU$) of the heat exchanger (round off to the nearest integer).

Answer Key:

2

Step-by-Step Solution & Explanation

$NTU = \frac{U A}{C_{\text{min}}} = \frac{8.0}{4.0} = 2.0$.