Question Bank • QB_SWCE_EXP_073 NAT • 2 Marks

Section 4: Soil and Water Conservation Engineering

Hydrology

Subtopic: Hydrological cycle and measurement of its components

Question Statement:

A catchment has 5 existing rain gauge stations with an average annual rainfall coefficient of variation $C_v = 30\%$. For an allowable percentage error in rainfall estimation of $\epsilon = 10\%$, calculate the optimal total number of rain gauge stations required ($N = (C_v / \epsilon)^2$).

Answer Key:

9

Step-by-Step Solution & Explanation

$N = \left(\frac{C_v}{\epsilon}\right)^2 = \left(\frac{30}{10}\right)^2 = 3^2 = 9$